FS2
Collective fireproof shelter

Designed for
Protection against direct fire and thermal radiation
Supply of breathable air
Emotional management
FS2 - Collective fireproof shelter
Product Features

Special multi-layer fabric
The FS2's multi-layer aluminized fabric provides exceptional insulation against heat and thermal radiation, delaying the transmission of flame energy into the shelter. In addition, its Kevlar seams give it high mechanical resistance, increasing the shelter's reliability.

Pneumatic structure
The shelter features a pneumatic support structure that inflates in seconds with the addition of breathable air, preventing direct contact between the fabric and the occupants and improving its protective properties. It also allows for a compact footprint when transporting.

Breathable air distribution system
Compatible with ERA and Carbotainer bottles. With individual masks for each occupant.

Lighting system
Mixed chemical-LED system for stress reduction during entrapment situations.
FS2 - Collective fireproof shelter
Advantages of using this product

Superior Protection
Provides effective protection against heat and fire.

Speed of deployment
Thanks to its pneumatic structure, it can be deployed in a matter of seconds.

Emotional management
It helps reduce stress and the risk of making impulsive and risky decisions.

Reliability
Made with highly heat-resistant materials and laboratory tested.
Includes the following components

Collective shelter with self-supporting pneumatic structure

Carrying bag

Deflation kit

12 liter air bottle
Optional

Oxygen meter
Optional

Geolocator
Optional
Regulations

of the European Parliament and of the Council of 10 May 2023 on general product safety.

of the European Parliament and of the Council of 16 September 2009 on the minimum health and safety requirements for the use of work equipment by workers at work.

EN ISO 15025 / ISO 9151 / EN ISO 6942 / ISO 12127-1 / ISO 17493 / EN ISO 13934-1 / EN ISO 13937-2 / EN ISO 13935-2
Accredited Notified Body Number: 0161
Test Report Number: 2017EP3190
In ISO 11612:
- A1 (ISO 15025, Procedure A)
- A2 (ISO 15025, Procedure B)
- B2 (ISO 9151)
- C4 (ISO 6942, Method B)
- F3 (ISO 12127-1)
- COMPLIES (ISO 17493)
- COMPLIES (ISO 13934-1)
- COMPLIES (ISO 13937-2)
- COMPLIES (ISO 13935-2)
In 469/A1:
- LEVEL 2 (ISO 9151)
- LEVEL 2 (ISO 6942, Method B)
- COMPLIES (ISO 17493)
- COMPLIES (ISO 13934-1)
- COMPLIES (ISO 13937-2)
- COMPLIES (ISO 13935-2)